12v Systems Minimum cable size to keep voltage drop to less than about 5%%

Cable length in metres.

Watts up to : Current up to: Absolute Minimum 3m 10m 30m 100m
36 W 3A 0.5 0.75 2.5 6 25
72 W 6A 0.75 1.5 4 10 35
120 W 10A 1 2.5 6 16 50
192 W 16A 1.5 2.5 10 25 --
288 W 24A 2.5 4 16 35 --
384 W 32A 4 6 16 50 --
480 W 40A 6 6 25 50 --
24v Systems Minimum cable size to keep voltage drop to less than about 5%

Cable length in metres.

Watts up to : Current up to: Absolute Minimum 3m 10m 30m 100m
72 W 3A 0.5 0.5 0.75 2.5 10
144 W 6A 0.75 0.75 1.5 4 16
240 W 10A 1 1 2.5 10 25
384 W 16A 1.5 1.5 4 16 50
576 W 24A 2.5 2.5 6 25 --
768 W 32A 4 4 10 25 --
960 W 40A 6 6 10 35 --